PRESSURE

890.gif (17519 bytes)QuikCal 890
The New QuikCal 890 Multifunction Calibrator from ALTEK

 

 

 

  • Generates and maintains pressure at the touch of a button
    no pump required.
  • Generates source pressures from 0.001 "H2O to 100 PSI.
  • Runs multipoint pressure, temperature, and DC tests simultaneously and instantly
  • Offers an unsurpassed accuracy of 0.025% of reading.
  • Pressure modules available for measurement of Gauge, Differential, Vacuum, Absolute, Compound, Draft and High Pressure; Additional Modules for Thermocouple, RTD and Electrical Signals.
  • The World’s First Fully Automated Pressure Source And The World’s Most Accurate Field Calibrator!

 

press.gif (21450 bytes)

 

ALTEK Modules: Expanding Capabilities

 

  • Pressure modules available for measurement of Gauge, Differential, Vacuum, Absolute, Compound, Draft and High Pressure; Additional Modules for Thermocouple, RTD and Electrical Signals.

 

PneuIII.jpg (17846 bytes) align=PneuCal III:
The one tool for both
pneumatic and pressure calibration.

  • Built-In Vacuum and Pressure Pumps
  • Built-in regulators precisely control pressures using standard shop air, nitrogen bottles, or any pressure source up to 100 lbs.
  • Measures and controls up to 100 PSI "out of the box"
  • Measures pressures from vacuum to 10,000 PSI, using the ModPak 91 Module Holder and ALTEK 90 Series external pressure modules. 
  • Simultaneous display of pressure and mA
  • Built-in 24V loop power supply
  • High Accuracy -- 0.035% FS
  • Switch Test Inputs
  • Temperature Compensated from -10°  to 50° C
    (13
    ° to 122° F)
  • Selectable Engineering Units
  • Dual Digital Display - PSI and mA
  • Gauge, Differential, or Vacuum Modes

 Each Unit Includes:  Built-In Switch Testing, AC Adapter/Charger, Test Leads, Hard Shell Carrying Case, Instructions, Built-In Pressure and Vacuum Pumps, Jack for connecting ALTEK 90-Series Pressure Modules via theModPack 91 Module Holder.


pneuiv.jpg (15421 bytes) PneuCal IV:  
For Troubleshooting, Calibrating,
and Repairing 3 – 15 PSI Pneumatic
Control Loops

  • Smaller, Lightweight Package - Less than 12 pounds!
  • Built-in regulators precisely control pressures using standard shop air, nitrogen bottles, or any pressure source up to 100 lbs
  • Measures -5PSI to 100 PSI
  • Simultaneous display of pressure and mA
  • Built-in 24V loop power supply
  • High Accuracy -- 0.035% FS
  • Switch Test Inputs
  • Temperature Compensated from -10°  to 50° C
      (13
    ° to 122° F)
  • Selectable Engineering Units
  • Dual Digital Display - PSI and mA
  • Gauge, Differential, or Vacuum Modes

 

Each Unit Includes:  Built-In Switch Testing, AC Adapter/Charger, Test Leads, Hard Shell Carrying Case, Instructions.


Model 1118 Quik-Touch PressureCalibrator
The Only Pressure Calibrator that Measures Pressure and Checks Pressure Switches.

  • Dependable Accuracy—
      (±0.05 of Span + 1 LSD).
  • Selectable Units— 
    Measures in psig, kPa, Pa, BAR, kgf/cm2, "Hg, mm Hg, "H20 and mm H2O.
  • Differential Models— 
    Clean gases or liquids to 10, 30 & 100 psi.
  • Isolated Models
    316 stainless diaphragms to 300, 1000 and 2000 psi.


Model 610 Digital Pressure Gauge
Single Instrument Replaces Several Test Gauges.
  • Easy-to-Use—
    Connect it up and select display units.
  • Selectable Units—
    psi, KPa, BAR, mBAR, mm Hg, "Hg, mm H2O, "H2O and kgF/cm2.
  • Sixteen Models—
    From vacuum to 10,000 psi.
  • Stainless Sensors—
    Gas and liquid compatible.
  • Min/Max— Monitors online pressures.


QuikCal 90 Pressure Module and Modpak 91 Module Holder
The NEW standard in Pressure Modules.
  • Laboratory Accuracy Pressure Measurement—
    Accurate to 0.025% of reading.
  • Twenty Engineering Units—
    PSI, Pa, kPa, MPa, BAR, mBAR, Atm, Kgf plus torr, inches and mm of mercury or water at a variety of temperatures.
  • Temperature Characterized—
    Laboratory accuracy in the shop, control room or field.
  • Modpak 91 Holds QuikCal 90 Modules For Connection To TechChek 830—
  • QuikCal Gauge Pressure Modules—
    QuikCal 90-5G
    QuikCal 90-10G
    QuikCal 90-30G
    QuikCal 90-100G
    QuikCal 90-300G
    QuikCal 90-500G
    QuikCal 90-1000G
    QuikCal 90-3000G
    QuikCal 90-5000G
    QuikCal 90-10000G
    0 to 5 PSIG
    0 to 10 PSIG
    0 to 30 PSIG
    0 to 100 PSIG
    0 to 300 PSIG
    0 to 500 PSIG
    0 to 1000 PSIG
    0 to 2500 PSIG
    0 to 5000 PSIG
    0 to 10000 PSIG
  • Dual Sensor Pressure Module—
    QuikCal 90-10G/2500    
    10/2,500 PSI
  • Absolute Pressure Modules—
    QuikCal 90-15A    0 to 15 PSIA

    QuikCal 90-30A    0 to 30PSIA
  • Compound Pressure Module—
    QuikCal 90-15C    Vacuum to 15 PSIG
  • Differential Pressure Module—
    QuikCal 90-5D
    QuikCal 90-15D
    QuikCal 90-30D

    0 to 5 PSID
    0 to 15 PSID
    0 to 30 PSID

  • Draft Range Pressure Module—
    QuikCal 90-10WD   
    ±10' H2OD
  • Vacuum Module—
    QuikCal 90-15V    Vacuum to 0 PSIG


Model 638 Precision High Pressure Pump
Faster Than Other Hand Pumps!
  • Portable Pressure Sources—
    Calibrate higher pressures without bottle gas or hydraulic fluid.
  • Choose from Two Ranges 638-600—
    600 psi, 41 BAR, 4135 kPa. 
    638-300—
    300 psi, 21 BAR, 2070 kPa.
  • Faster and Easier—
    Larger cylinder and compound mechanism generate 100 psi 2 to 4 times faster than other pumps.
  • Precise Setting to 0.001 psi—
  • Patented micro bleed valve and "balanced pressure" for quick, easy adjustment.
  • Dual Output Ports—
    Simultaneous connection to calibrator and device being calibrated.
  • Easy to Rebuild—
    Replace the o-rings in under ten minutes.

 


Model 628, 618P & 618V Handheld Pressure & Vacuum Pumps
Compact and Economical!

Precision Pressure PumpModel 628: 

  • Convenient, One Handed Operation—
    Easily generates pressure to 100 PSI or 7 BAR.
  • Dual Output Ports—
    Simultaneous connection to calibrator and device being calibrated.
  • Fine Adjustments—
    Set to within 0.001 psi. 

 

Pressure Pump Model 618P:

  • Easy-to-Carry—
    Small and lightweight to go in your toolbox. Pressure up to 145 psi or 10 BAR.
  • Economical—
    Every technician can have one of their own.

Vacuum Pump Model 618V:

  • Easy-to-Use—
    Pulls a vacuum to 600mm or 23 "Hg; 7620mm or 300" H20 or 11 psi.

 

 

 

ALTEK INDUSTRIES CORP
35 Vantage Point Drive
Rochester, New York 14624 U.S.A.
Phone 716-349-3500  Fax 716-349-3510
Sales Email ALTEKsales@ALTEKcalibrators.com  
Service Email ALTEKservice@ALTEKcalibrators.com